Приказ основних података о документу

dc.creatorŽupunski, Vesna
dc.creatorNikolić, Zorica
dc.creatorZdjelar, Gordana
dc.creatorJovičić, Dušica
dc.creatorIgnjatov, Maja
dc.creatorMilošević, Dragana
dc.creatorTamindžić, Gordana
dc.date.accessioned2022-08-11T11:04:30Z
dc.date.available2022-08-11T11:04:30Z
dc.date.issued2013
dc.identifier.isbn978-86-80417-44-8
dc.identifier.urihttp://fiver.ifvcns.rs/handle/123456789/3013
dc.description.abstractMeasurement of proteinase inhibitor activity of legume seeds is widely used since some of these exert toxic and antinutritional effects. Standard method assay for trypsin inhibitor activity (TIA) determination is based on the hydrolysis of benzoyl-DL-arginine-p-nitroanilide (BAPA) by trypsin and includes spectrophotometric measurement of the reaction products. Assaying of trypsin inhibitor activity is usualy performed using reaction mixture volumes of 4-10 ml, however, it was shown that microtitration method can also be used for TIA determination. Although the results obtained by microtitration method were consistent with those obtained by French Association for Normalization reference method (AFNOR), it was noted that any experimental error in absorbance values was increasingly magnified as the sample size was diminshed. The aim of this study was to analyse measurement uncertanty of TIA determination using microtiter plate method. Assaying procedure was conducted at 37 °C on sample (soybean variety Vojvoñanka), positive and negative control, which were set in four replicats in each row of the microtiter plate, with preincubation time of 10 minutes and incubation time of 30 minutes. The trypsin inhibitor activity was expresed in number of trypsin units inhibited (TUI) per miligram of sample, taking into account the fact that one trypsin unit is defined as an increase of 0.01 absorbance units at 405 nm. Large number of experiments was conducted and uncertainty analysis was obtained using uncertainty budget. Values of calculated trypsin inhibitor activity were approximately 70 TUI/mg and estimated expanded measurement uncertainty (with coverage factor k=2) was aproxitemately 15%.sr
dc.language.isoensr
dc.publisherInternational Legume Societysr
dc.publisherNovi Sad : Institute of Field and Vegetable Cropssr
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/31022/RS//sr
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/31024/RS//sr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceBook of Abstracts, 1st Legume Society Conference 2013: A Legume Odyssey, 9-11 May 2013, Novi Sadsr
dc.subjecttrypsin inhibitor activitysr
dc.subjectmicrotiter platesr
dc.subjectanalysissr
dc.titleUncertainty analysis of trypsin inhibitor activity determination using microtiter plate methodsr
dc.typeconferenceObjectsr
dc.rights.licenseBYsr
dc.citation.epage131
dc.citation.spage131
dc.identifier.fulltexthttp://fiver.ifvcns.rs/bitstream/id/8405/132.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_fiver_3013
dc.type.versionpublishedVersionsr


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу