A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid
Poređenje različitih metoda za uklanjanje rastvorenog kiseonika - primena pri elektrohemijskom određivanju imidakloprida

2015
Authors
Đurović, Ana
Stojanović, Zorica

Kravić, Snežana

Suturović, Zvonimir

Brezo, Tanja
Grahovac, Nada

Milanović, Spasenija D.
Article (Published version)
Metadata
Show full item recordAbstract
This study compares different methods for the removal of oxygen from the solution prior to the chronopotentiometric determination of the insecticide imidacloprid on glassy carbon electrode. The research included the application of the chemical method involving addition of sulfite ion, and the physical method of purging the sample with nitrogen stream, as well as their combination. By comparing analytical signals of imidacloprid, chemical method showed almost the same efficiency as conventional physical method, while the best reproducibility was achieved by applying chemical method with addition of the saturated sodium sulfite solution. The method is very simple and can be applied for deoxygenation of the solution prior to the chronopotentiometric analysis. The application of the chemical deoxygenation significantly shortened duration of the chronopotentiometric analysis of imidacloprid from approximately 15 min to 1 min.
U ovoj studiji poređene su različite metode za uklanjanje rastvorenog kiseonika iz rastvora pre hronopotenciometrijskog određivanja insekticida imidakloprida na elektrodi od staklastog ugljenika. Istraživanje je obuhvatalo primenu hemijske metode dodatkom sulfitnog jona i fizičke metode provođenje struje azota kroz uzorak u trajanju od 5, 10 i 15 min, kao i njihovu kombinaciju. Poređenjem analitičkih signala imidakloprida, hemijska metoda pokazala je skoro istu efikasnost kao i konvencionalna fizička metoda, dok je najbolja reproduktivnost ostvarena primenom hemijske metode uz dodatak 0,8 cm3 zasićenog rastvora natrijum sulfita. Metoda je veoma jednostavna i može se primeniti za uklanjanje kiseonika iz rastvora pre izvođenja hronopotenciometrijske analize. Primenom hemijske deoksigenacije značajno se skraćuje trajanje hronopotenciometrijske analize imidakloprida sa 15 min na 1 min.
Keywords:
imidacloprid / sulfite ion / chemical deoxygenation / imidakloprid / sulfitni jon / hemijska deoksigenacijaSource:
Acta Periodica Technologica, 2015, 46, 149-155Publisher:
- Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad
Funding / projects:
Collections
Institution/Community
FiVeRTY - JOUR AU - Đurović, Ana AU - Stojanović, Zorica AU - Kravić, Snežana AU - Suturović, Zvonimir AU - Brezo, Tanja AU - Grahovac, Nada AU - Milanović, Spasenija D. PY - 2015 UR - http://fiver.ifvcns.rs/handle/123456789/1496 AB - This study compares different methods for the removal of oxygen from the solution prior to the chronopotentiometric determination of the insecticide imidacloprid on glassy carbon electrode. The research included the application of the chemical method involving addition of sulfite ion, and the physical method of purging the sample with nitrogen stream, as well as their combination. By comparing analytical signals of imidacloprid, chemical method showed almost the same efficiency as conventional physical method, while the best reproducibility was achieved by applying chemical method with addition of the saturated sodium sulfite solution. The method is very simple and can be applied for deoxygenation of the solution prior to the chronopotentiometric analysis. The application of the chemical deoxygenation significantly shortened duration of the chronopotentiometric analysis of imidacloprid from approximately 15 min to 1 min. AB - U ovoj studiji poređene su različite metode za uklanjanje rastvorenog kiseonika iz rastvora pre hronopotenciometrijskog određivanja insekticida imidakloprida na elektrodi od staklastog ugljenika. Istraživanje je obuhvatalo primenu hemijske metode dodatkom sulfitnog jona i fizičke metode provođenje struje azota kroz uzorak u trajanju od 5, 10 i 15 min, kao i njihovu kombinaciju. Poređenjem analitičkih signala imidakloprida, hemijska metoda pokazala je skoro istu efikasnost kao i konvencionalna fizička metoda, dok je najbolja reproduktivnost ostvarena primenom hemijske metode uz dodatak 0,8 cm3 zasićenog rastvora natrijum sulfita. Metoda je veoma jednostavna i može se primeniti za uklanjanje kiseonika iz rastvora pre izvođenja hronopotenciometrijske analize. Primenom hemijske deoksigenacije značajno se skraćuje trajanje hronopotenciometrijske analize imidakloprida sa 15 min na 1 min. PB - Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad T2 - Acta Periodica Technologica T1 - A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid T1 - Poređenje različitih metoda za uklanjanje rastvorenog kiseonika - primena pri elektrohemijskom određivanju imidakloprida EP - 155 SP - 149 VL - 46 DO - 10.2298/APT1546149D ER -
@article{ author = "Đurović, Ana and Stojanović, Zorica and Kravić, Snežana and Suturović, Zvonimir and Brezo, Tanja and Grahovac, Nada and Milanović, Spasenija D.", year = "2015", abstract = "This study compares different methods for the removal of oxygen from the solution prior to the chronopotentiometric determination of the insecticide imidacloprid on glassy carbon electrode. The research included the application of the chemical method involving addition of sulfite ion, and the physical method of purging the sample with nitrogen stream, as well as their combination. By comparing analytical signals of imidacloprid, chemical method showed almost the same efficiency as conventional physical method, while the best reproducibility was achieved by applying chemical method with addition of the saturated sodium sulfite solution. The method is very simple and can be applied for deoxygenation of the solution prior to the chronopotentiometric analysis. The application of the chemical deoxygenation significantly shortened duration of the chronopotentiometric analysis of imidacloprid from approximately 15 min to 1 min., U ovoj studiji poređene su različite metode za uklanjanje rastvorenog kiseonika iz rastvora pre hronopotenciometrijskog određivanja insekticida imidakloprida na elektrodi od staklastog ugljenika. Istraživanje je obuhvatalo primenu hemijske metode dodatkom sulfitnog jona i fizičke metode provođenje struje azota kroz uzorak u trajanju od 5, 10 i 15 min, kao i njihovu kombinaciju. Poređenjem analitičkih signala imidakloprida, hemijska metoda pokazala je skoro istu efikasnost kao i konvencionalna fizička metoda, dok je najbolja reproduktivnost ostvarena primenom hemijske metode uz dodatak 0,8 cm3 zasićenog rastvora natrijum sulfita. Metoda je veoma jednostavna i može se primeniti za uklanjanje kiseonika iz rastvora pre izvođenja hronopotenciometrijske analize. Primenom hemijske deoksigenacije značajno se skraćuje trajanje hronopotenciometrijske analize imidakloprida sa 15 min na 1 min.", publisher = "Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad", journal = "Acta Periodica Technologica", title = "A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid, Poređenje različitih metoda za uklanjanje rastvorenog kiseonika - primena pri elektrohemijskom određivanju imidakloprida", pages = "155-149", volume = "46", doi = "10.2298/APT1546149D" }
Đurović, A., Stojanović, Z., Kravić, S., Suturović, Z., Brezo, T., Grahovac, N.,& Milanović, S. D.. (2015). A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid. in Acta Periodica Technologica Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad., 46, 149-155. https://doi.org/10.2298/APT1546149D
Đurović A, Stojanović Z, Kravić S, Suturović Z, Brezo T, Grahovac N, Milanović SD. A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid. in Acta Periodica Technologica. 2015;46:149-155. doi:10.2298/APT1546149D .
Đurović, Ana, Stojanović, Zorica, Kravić, Snežana, Suturović, Zvonimir, Brezo, Tanja, Grahovac, Nada, Milanović, Spasenija D., "A comparison of different methods to remove dissolved oxygen: Application to the electrochemical determination of imidacloprid" in Acta Periodica Technologica, 46 (2015):149-155, https://doi.org/10.2298/APT1546149D . .