Novel electrochemical procedure for the determination of metamitron

Đurović, Ana; Stojanović, Zorica; Kravić, Snežana; Rakić, Dušan; Grahovac, Nada

(Taylor & Francis Ltd, Abingdon, 2018)

TY  - JOUR
AU  - Đurović, Ana
AU  - Stojanović, Zorica
AU  - Kravić, Snežana
AU  - Rakić, Dušan
AU  - Grahovac, Nada
PY  - 2018
UR  - http://fiver.ifvcns.rs/handle/123456789/1792
AB  - In this paper, a chronopotentiometric method for the determination of herbicide metamitron (MTM) using a glassy carbon electrode (GCE) and a thin film mercury electrode (TFME) as working electrodes is presented. MTM provided a well-defined reductive peak in the Britton-Robinson buffer on both working electrodes. Instrumental and chemical factors such as pH of the buffer, initial potential and reduction current influencing MTM chronopotentiometric response were optimised with the Box-Behnken experimental design. Under the optimal combination of factors, the analytical signal was linear in the MTM concentration range of 0.8-30mg/L, with a detection limit of 68.53 mu g/L using a TFME, and in the concentration range of 1-30mg/L, with a detection limit of 92.91 mu g/L using a GCE. The precision of the method was estimated as a function of repeatability and reproducibility, with the value of relative standard deviation lower than 2.6%. The applicability of the method was verified by direct analysis of MTM in spiked water samples and commercial pesticide formulations. The obtained results were in good agreement with those obtained using liquid chromatography/tandem mass spectrometry (LC-MS/MS) method, or with those labelled by the manufacturer. By using chronopotentiometry, neither extraction nor preconcentration procedures are necessary, thus making this method simple, cost-effective and more feasible for analytical routine analysis.
PB  - Taylor & Francis Ltd, Abingdon
T2  - International Journal of Environmental Analytical Chemistry
T1  - Novel electrochemical procedure for the determination of metamitron
EP  - 385
IS  - 4
SP  - 369
VL  - 98
DO  - 10.1080/03067319.2018.1469625
ER  - 
@article{
author = "Đurović, Ana and Stojanović, Zorica and Kravić, Snežana and Rakić, Dušan and Grahovac, Nada",
year = "2018",
abstract = "In this paper, a chronopotentiometric method for the determination of herbicide metamitron (MTM) using a glassy carbon electrode (GCE) and a thin film mercury electrode (TFME) as working electrodes is presented. MTM provided a well-defined reductive peak in the Britton-Robinson buffer on both working electrodes. Instrumental and chemical factors such as pH of the buffer, initial potential and reduction current influencing MTM chronopotentiometric response were optimised with the Box-Behnken experimental design. Under the optimal combination of factors, the analytical signal was linear in the MTM concentration range of 0.8-30mg/L, with a detection limit of 68.53 mu g/L using a TFME, and in the concentration range of 1-30mg/L, with a detection limit of 92.91 mu g/L using a GCE. The precision of the method was estimated as a function of repeatability and reproducibility, with the value of relative standard deviation lower than 2.6%. The applicability of the method was verified by direct analysis of MTM in spiked water samples and commercial pesticide formulations. The obtained results were in good agreement with those obtained using liquid chromatography/tandem mass spectrometry (LC-MS/MS) method, or with those labelled by the manufacturer. By using chronopotentiometry, neither extraction nor preconcentration procedures are necessary, thus making this method simple, cost-effective and more feasible for analytical routine analysis.",
publisher = "Taylor & Francis Ltd, Abingdon",
journal = "International Journal of Environmental Analytical Chemistry",
title = "Novel electrochemical procedure for the determination of metamitron",
pages = "385-369",
number = "4",
volume = "98",
doi = "10.1080/03067319.2018.1469625"
}
Đurović, A., Stojanović, Z., Kravić, S., Rakić, D.,& Grahovac, N.. (2018). Novel electrochemical procedure for the determination of metamitron. in International Journal of Environmental Analytical Chemistry
Taylor & Francis Ltd, Abingdon., 98(4), 369-385.
https://doi.org/10.1080/03067319.2018.1469625
Đurović A, Stojanović Z, Kravić S, Rakić D, Grahovac N. Novel electrochemical procedure for the determination of metamitron. in International Journal of Environmental Analytical Chemistry. 2018;98(4):369-385.
doi:10.1080/03067319.2018.1469625 .
Đurović, Ana, Stojanović, Zorica, Kravić, Snežana, Rakić, Dušan, Grahovac, Nada, "Novel electrochemical procedure for the determination of metamitron" in International Journal of Environmental Analytical Chemistry, 98, no. 4 (2018):369-385,
https://doi.org/10.1080/03067319.2018.1469625 . .